Dongguan Xin Bao Instrument Co., Ltd.

 

Your Leader in Reliability Test Equipment - Since 1978

Home ProductsLab Test Chamber

40kg Automatic Residual Indentation Tester Lab Test Chamber

Certification
China Dongguan Xinbao Instrument Co., Ltd. certification
China Dongguan Xinbao Instrument Co., Ltd. certification
This is my second cooperation with OTS, the machine is very good, and fast service. Look forward our next order.

—— Vinod Kumar Pandey

OTS is a very professional manufacturer for our customized machine. The quality is very surprising under such a friendly price.

—— Kohut Gabor

I visited OTS factory before order. I like their production machines, and experienced technicians. Now we have annual order from them, it is always a happy cooperation with them.

—— Chris 

I'm Online Chat Now

40kg Automatic Residual Indentation Tester Lab Test Chamber

40kg Automatic Residual Indentation Tester Lab Test Chamber
40kg Automatic Residual Indentation Tester Lab Test Chamber

Large Image :  40kg Automatic Residual Indentation Tester Lab Test Chamber

Product Details:
Place of Origin: Dongguan China
Brand Name: OTS
Certification: CE ISO9001
Model Number: Lab Test Chamber
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: Strong standard wood case, inner plastic films wrapped for RoHS Energy Dispersive X-Ray Fluorescence Spectrometer XRF Analyzer
Delivery Time: 20 working day after getting the payment
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 100 Unit/Units per Month
Detailed Product Description
Key Words: Automatic Residual Indentation Tester Weight: 40kg
Power: 220V Sample Space: (20~70)mm
Dimensions: About L200×D320×H576mm Test Station: Single Station
Brand: OTS Sample Specifications: 60x60mm And 50x50mm
High Light:

Automatic Residual Indentation Tester

,

40kg Lab Test Chamber

,

40kg Residual Indentation Tester

Arbitrary Settings Within The 0~600min Range Automatic Residual Indentation Tester​

 



Product Description:

 

The test machine determines a method of residual sag, which is produced by applying and removing a

constant load on an elastic or flake floor coating. The difference between the initial thickness and the

thickness measured after the load is removed, and the distance between the two parallel plates is the

lower part of the material under the specified loading force. The specimen is subjected to static force,

measuring the thickness before the application force and the thickness after the recovery period.

 

 

3. technical parameters:

 

Test standard EN433,ISO24343-1/2,GB4085,ASTM F1914,ASTM F970
Loading mode Automatic loading, automatic surveying
Test features Fully automatic one-click completion of residual sag, thickness measurement
Test Station Single Station
Sample Space (20~70)mm
Sample Specifications 60x60mm and 50x50mm
Load 0~2000N Can be set within the range
Load Header Ф(11.30±0.05)mm and Ф(4.521±0.0127)mm
Pressure holding time Arbitrary settings within the 0~600min range
Power 220V
Dimensions About L200×D320×H576mm
Weight About 40kg



40kg Automatic Residual Indentation Tester Lab Test Chamber 0
 

EN433,ISO24343-1/2
European Standard Test steps
ASTM F1914,ASTM F970
American Standard test steps
Fully automated test steps
and features(While meeting
EN433,ISO24343-1/2,
GB4085,ASTM F1914,
ASTM F970)
1. Cut the sample, first use the
thickness meter to measure
the original thickness of the
product, recorded as T0;
1. Cut the sample, first use the
thickness meter to measure the
original thickness of the
product, recorded as T1
1. Libang according to
European Standard and the
United States standard two
test methods, the preparation
of PLC procedures, testing,
only the selection of test
standards, the sample placed
the corresponding pressure
head, the machine
automatically one-click to
complete a series of test
steps and automatically save
data, without personnel
timing, manual measurement,
waiting and avoid the error of
manual operation of
personnel. 2. The system has
automatic timing, automatic
thickness measurement
device.
Automatically stops after the
test is completed,
automatically saves the test
results of the display sample
and the graph of the test
process, and can output the
test report via the USB
interface.
3. Machine with automatic
positioning function, can save
an operation engineer, fully
automatic one-click to
complete (European
Standard and American
standard) test.
2. Placing the specimen on
the test bench is under the
loading head;
2. Place the specimen under
the loading head, rotate the
weight loading device until the
weight loader leaves the
loading head adapter lever,
clear 0 thickness meter;
3. The control weight is
applied to the initial load of 3N
in 5 seconds, and the
recording thickness is TA.
Manually increase the weight
to reach the total load to start
the stopwatch timing in 500n,2
seconds (holding time);
3. Manually load the
appropriate weight weights by
standard and required test
methods;
4. Test load pressurized and
start timing, pressurized after
150min, recording sag depth
recorded as TB;
4. The rotary weight loader
loads all weight weights on the
loading load, starts timing,
records the current sample
thickness after recording, and
is recorded as T2;
5. After removing the load,
after placing 150min, the
measurement thickness is
recorded as T1 using the
thickness meter;
5. The rotating weight loading
device Releases the weight,
the sample naturally relaxes
and restores 60min to measure
the sample thickness again,
recorded as T3;
Calculation:Manual
calculation and statistics of
the above data according to
the requirements and
formulas within the standard
Calculation: Manual calculation
and statistics of the above data
according to the requirements
and formulas within the
standard

Contact Details
Dongguan Xinbao Instrument Co., Ltd.

Contact Person: Andy Xiao

Send your inquiry directly to us (0 / 3000)